BSKQB - NICKEL CADMIUM CELLS AEROSPACE

  • MSDS: BSKQB
  • Manufacturer: GATES ENERGY PRODUCTS
  • Product Name: NICKEL CADMIUM CELLS AEROSPACE
  • National Stock Number: 6140-00N047522
Product Identification

Product ID:NICKEL CADMIUM CELLS AEROSPACE
MSDS Date:10/28/1987
FSC:6140
NIIN:00N047522
MSDS Number: BSKQB

Responsible Party
GATES ENERGY PRODUCTS
GAINESVILLE, FL 32602
US

Emergency Phone: 904-462-3911

Info Phone: 904-462-3911

Cage: 19209

Contractor
ENERGIZER POWER SYSTEMS (FORMALLY GATES ENERGY PRODUCTS
147114 GAINESVILLE, FL 32614-7114 US

Telephone: 904-462-3911

Cage: 19209

Ingredients

NICKEL

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 20-30%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.05 MG/M3


NICKEL HYDROXIDE

OSHA PEL N/K

ACGIH TLV: N/K


CADMIUM

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: 13-15%

OSHA PEL 0.2 MG/M3

ACGIH TLV: 0.1 MG/M3

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


POTASSIUM HYDROXIDE

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 2-04%

OSHA PEL 2.0 MG/M3, C

ACGIH TLV: 2.0 MG/M3, C

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


COBALT

CAS: 7440-48-4

RTECS: GF8750000

Fraction By Weight: 1-2%

OSHA PEL 0.1 MG/M3

ACGIH TLV: 0.1 MG/M3


COBALT HYDROXIDE

CAS: 1307-86-4

RTECS: GG0904000

OSHA PEL N/K

ACGIH TLV: N/K


CADMIUM HYDROXIDE

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ELECTROLYTE IS CAUSTIC. CONTACT WITH
SKIN OR EYES MAY CAUSE IRRITATION.
Explanation of Carcinogenicity:CADMIUM: IARC MONOGRAPHS, SUPPLEMENT,
VOL 7, PG 139,. 1987: GRP 2A. NTP 6TH ANNUAL REPORT ON CARCINS,
1991: (SUPP DATA)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE/SKIN: FLUSH W/PLENTY OF RUNNING WATER FOR AT LEAST 15 MIN
AND CONTACT A PHYSICIAN. INHAL: REMOVE TO FRESH AIR SUPPORT
BREATHING (GIVE O*2/ARTF RESP). INGEST: GET MD IMMEDIATELY .

Fire Fighting

Extinguishing Media:EXTINGUISHING MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CADMIUM FUMES MAY BE RELEASED DURING
BURNING.

Accidental Release

Spill Release Procedures:FLUSH ELECTROLYTE SPILLS WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT SHORT CIRCUIT; MAY CAUSE BURNS.
Other Precautions:AVOID INCINERATION OR MUTILATION.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:ANTICIPATED TO BE CARCIN. NICKEL: IARC MONOGRAPHS ON
THE EVAL OF CARCIN RISK OF CHEMS TO MAN, VOL 49 PG 257, 1990: GRP
2B. NTP 6TH ANNUAL REPORT ON CARCINS, 1991: ANTICIPATED TO BE CA
RCIN. COBALT & COBALT HYDROXIDE: IARC MONOGRAPHS ON THE EVAL OF
CARCIN RISK OF CHEMS TO MAN, VOL 52, P 363, 1991:GRP 2B.

Chemical Properties

HCC:N1

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:DO NOT INCINERATE OR MUTILATE; MAY
BURST OR RELEASE TOXIC MATERIALS.

Disposal

Waste Disposal Methods:IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.